17
TIPS FOR CORRECT USE
To ensure optimal results from your air conditioner, follow these
recommendations:
• Close the windows and doors in the room to be air condi-
tioned. When installing the air conditioner semi-perma-
nently, you should leave a door slightly open (as little as 1
cm) to guarantee proper ventilation.
• Never use the appliance in very damp rooms (laundries for
example).
• Protect the room from direct exposure to the sun by par-
tially closing curtains and/or blinds to make the appliance
much more economical to run.
• Never use the appliance outdoors.
•
Make sure there are no heat sources in the room.
• Make sure the air conditioner is standing on a level surface.
don’t cover the appliance
• Never rest objects of any kind on the air conditioner.
• Never obstruct the air intake or air outlet grilles.
CLEANING
Before cleaning or maintenance, turn the appliance o by
pressing the
C1C2
C4
C13
C12
C9
C7
C5
C6
C3
C14
C10
C15
C11
C8
button, then unplug from the outlet.
CLEANING THE CABINET
You should clean the appliance with a slightly damp cloth then
dry with a dry cloth. For safety reasons, never wash the air con-
ditioner with water.
Attention! Never use petrol, alcohol or solvents to clean the ap-
pliance. Never spray insecticide liquids or similar.
CLEANING THE AIR FILTER
To maintain the eciency of the air conditioner, it is recom-
mended to clean the dust lter after every week of use. The lter
is located on the intake grille (A6). To clean the lter, it must be
removed as shown in gure 11. Use a vacuum cleaner to remove
any dust. If it is very dirty, submerge it in warm water and rinse it
several times. The water temperature must be kept below 40° C.
After washing the lter, allow it to dry.
To replace, put the lter back in its housing
CHECKS AT THE BEGINNING OF THE SEASON
Make sure the power cable and socket are in perfect condition
and make sure the earthing system is ecient. Comply strictly
with the installation standards.
END OF SEASON OPERATIONS
To completely drain the water from the internal circuit, remove
the cap from the lower drainage hose, turning it counter clock-
wise then remove the internal cap (Fig. 12).
Drain the water completely into a basin. When it is complete-
ly drained, replace the caps, making sure they are completely
closed.
Clean the lter as indicated previously. The lter must be com-
pletely dry before reinserting it.
TECHNICAL SPECIFICATIONS
Power supply voltage see rating label
Max. absorbed power
during air conditioning “
Refrigerant “
Cooling capacity “
LIMIT CONDITIONS
Room temperature for air conditioning 18° ÷ 35°C
Transporting, loading, cleaning, recovery and disposal of
the refrigerant must only be performed by technical ser-
vice centres authorised by the manufacturing company.
The appliance must only be disposed of by specialised
personnel authorised by the manufacturing company.
Attention! TO AVOID DAMAGE TO THE UNIT:
NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR
ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING
THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. After the unit
has been on its side, oil needs to return to the compressor to en-
sure proper function. Without allowing the unit this time (6-24
hours) the unit may function for only a short time, and then the
compressor will break down from lack of oil.