Yamaha RD-500 Návod k obsluze

Typ
Návod k obsluze

Tato příručka je také vhodná pro

MULTI-FRAME PARTS
MULTIPLER BEFESTIGUNGSRAHMEN
CHÂSSIS MULTI SUPPORT
SOPORTE BASTIDOR MULTIPERCUSIÓN
English
Deutsch
Français Español
RD500
XYLOPHONE
XYLOPHON
XYLOPHONE
XILÓFONO
YX500FT
Carefully read the contents of this manual, especially all precautions.
Lesen Sie unbedingt die „Vorsichtshinweise für die Handhabung der Gasfeder“ und die „Vorsichtsmaßregeln“.
Lire attentivement les paragraphes « Précautions de manipulation du ressort à gaz » et « Précautions à observer ».
Lea sin falta las “Precauciones para la manipulación del muelle de gas” y las “Precauciones”.
“가스 스프링 취급상의 주의사항” 및 “주의사항” 을 반드시 읽어 주십시오 .
/ Owner’s Manual / Bedienungsanleitung /
Mode d’emploi / Manual de instrucciones / /
8
Precautions
Before using please thoroughly read the following precautions, instructions and explanations
on handling and using the instrument safely.
When assembling or disassembling the rack or xylophone, please observe the following precautions.
Especially in the case of children, a responsible adult should provide instruction
on the proper use and treatment of the instrument.
Preventing Injuries
—Obey all precautions described below
About
the
Icons
Icons are used in this section to promote the safe
and proper use of this product and to prevent
harm and property damage to you and others.
Please fully understand the meaning of the icons
before reading the manual.
This icon indicates actions that are prohibited.
This icon urges you to pay caution (includes dangers and
warnings).
This icon indicates instructions that should be strictly
followed
Warning
Disregard of the warnings with this mark or misuse may
result in death or serious injury.
Instrument Placement
Do not place the instrument on an unstable surface
such as a slope or uneven surface.
The instrument may fall or overturn resulting in injury.
Instrument Handling
Do not lean on or climb on the instrument.
The instrument may fall causing serious injury.
Do not play around the instrument.
It may cause the instrument to fall over. Bumping into
the instrument may result in injury.
Keep away from the instrument during earthquakes.
Strong tremors can cause the instrument to move about
or overturn.
Do not mount any instruments other than those rec-
ommended for mounting on the RD500.
The RD500 rack is specially designed for use with the
YX335 and YX500FT. Do not modify any instrument
for installing on the rack. Doing so can result in the
instrument dropping off resulting in serious injury. The
YX500R and YX500F cannot be mounted on the rack.
Do not attach optional instruments to the rack with
poor balance.
Because the rack can overturn or the optional instru-
ments can drop off, this is extremely dangerous. Always
make sure that the instruments are attached to the rack
using the specially designed clamps, and that they are
positioned to provide good balance on the rack. Attach-
ing instruments in a poorly balanced manner outside of
the rack frame or rack pipe can cause the instrument to
overturn.
Always assemble/disassemble the instrument on a
at surface.
When assembling or disassembling the rack and at-
taching or removing the optional instruments, always
work on a flat, solid surface. Working on an unstable
surface such as a shaky table or sloped surface can
cause the instrument to overturn.
Make sure that all nuts and bolts are rmly tightened
before using the instrument.
Firmly tighten all nuts and bolts on each part after their
positions have been determined. Using the instrument
with loose nuts or bolts can cause the rack to overturn
or instruments to drop off. Make sue that all nuts and
bolts are rmly retightened before using the instrument.
Always remove the optional instrument before ad-
justing its height or angle.
When adjusting the height or angle of heavy optional
instruments such as marching bells, chimes, etc., re-
move the instruments first and then adjust. Adjusting
the instruments while attached to the rack can result in
pinched hands or ngers causing injury.
Instrument Movement
Do not run while pushing the instrument.
The instrument may become impossible to stop, crash
into a wall, and cause serious injury.
Never carry the assembled instrument up or down
the stairs.
Parts may fall off, or you may loose balance resulting
in serious injury. Only move the instrument after it has
been disassembled.
Never try lifting the instrument by yourself when
moving the instrument.
Lifting the instrument by yourself can result in pinched
limbs, back injury, or other serious injury. The instrument
should always be moved using at least two persons
holding the rack by the leg center rail (see page 11) with
both hands.
* The YX500FT weighs approximately 27kg. When at-
tached to the RD500, their combined weight is 60kg.
When moving the instrument on its casters, hold the
upper leg section and push forward slowly across
smooth, at surfaces.
Moving the instrument on sloped, uneven, or graveled
surfaces can result in the instrument overturning or run-
ning away out of control.
[Good balance] [Poor balance]
9
Caution
Disregard of cautions with this mark or misuse may result
in personal injury or the loss of personal property.
Precautions Regarding the Gas Spring
Please observe the following instructions for proper handling of the gas spring.
* Refer to page 13 for gas spring removal.
Caution
Disregard of cautions with this mark or misuse may
result in personal injury or the loss of personal property.
Be careful not to pinch your ngers or hands when
assembling.
Doing so may cause injury due to pinched ngers, etc.
When assembling legs, reinforcement stays, and reso-
nator pipes, use two persons taking special care to
double-check each other as the assembly proceeds.
Always make sure that the wing bolts and wing nuts
are rmly tightened to prevent parts from becoming
loose during performance.
Using the instrument with loose bolts and nuts can
cause trouble during performance such as unexpected
movement, etc., or parts falling off during transport re-
sulting in injury.
Refer to the instructions when assembling the rack.
Height adjustment should always be performed with
at least two persons.
Make sure that all procedures described in the manual
are followed when assembling the rack and attaching
or removing the xylophone. Disobeying the procedures
can result in parts falling off from the rack during as-
sembly, which can be dangerous. Also, height adjust-
ment should always be performed by at least two
persons. If it is absolutely necessary to adjust height by
one person, do not make adjustments of more than two
notches on the slide guides at a time (see page 13).
Handling
Only use genuine Yamaha clamps.
Never use clamps that do not properly t on the rack pipe,
etc. when making attachments. Doing so can cause the rack
to overturn or instruments to fall off resulting in serious injury.
Never loosen the slide guide xing bolt when the xy-
lophone is not mounted on the rack.
Never loosen the slide guide xing bolts when the xylophone
is not mounted on the rack or when the legs are not attached
to the rack (except for when removing the gas spring). Doing
so is extremely dangerous because the rack frame (see page
11) can rise suddenly causing an accident or injury.
Limits to attaching optional instruments
The total weight of optional instruments must not ex-
ceed 18kg. Attaching more weight can result in the
entire rack overturning, becoming damaged, or the
optional instruments falling off or becoming damaged.
This is extremely dangerous.
Do not touch cracked tone bars.
Cracked tone bars have sharp edges that can cut hands.
Please change cracked tone bars as soon as possible.
Do not use the mallets for any other purpose than
playing the instrument.
Misuse of the mallets may result in unexpected injury or
accidents.
In the event of a failure, stop using the instrument and contact the
shop where you purchased it. If your dealer is unable to assist you,
please contact Yamaha directly as per enclosure.
Cautions when discarding the gas spring
Pressurized nitrogen gas is sealed inside
of the gas spring. Be sure to release the
gas before discarding the gas spring, or
an explosion can occur, causing injury.
[Cautions]
• Do not push.
• Do not cut the gas spring.
• Do not throw the gas spring into a re.
• Do not make a hole anywhere in the gas
spring other than in the speci ed posi-
tions (
q
and
w
in the gure below).
[Discarding procedure]
1. Put the gas spring in a plastic bag. Using
a drill of 2 to 3 mm, make a hole
q
from
outside of the plastic bag at the position as
speci ed in the gure to release the gas and
oil and then make a hole
w
at the position
as speci ed. (Be sure to make holes in the
order of
q
and
w
.)
2. If a vinyl bag is not used, the oil and drill
chips will spread. (In such a case, wear eye
protection glasses. )
q
w
35mm
Drill
Plastic
bag
15mm
* Drill two holes, as shown above, to release
the gas before discarding the gas spring.
Danger!
Disregarding any caution with this
mark can place you in imminent danger
resulting in death or serious injury.
Handling
Never lubricate the moving parts on the gas spring.
Lubricating the gas spring will reduce the durability of the seal and
cause oil leakage.
Do not expose to impacts.
Doing so will cause oil leakage, malfunction, or damage.
Never dismantle.
High-pressure gas is sealed inside of the gas spring, so any at-
tempt to disassemble it is extremely dangerous.
Do not bend.
The rod is susceptible to bending from directional loads. A poorly bal-
anced load placed on the rod can result in bending and malfunction.
Do not hit.
Hitting the piston rod or cylinder can shorten the life of the seal or
result in malfunction.
Do not expose the instrument to excessively high or low temperatures.
Doing so can cause malfunction. Use the instrument only in tem-
peratures ranging from -20ºC to 50ºC.
Do not expose the instrument to rain, moisture or dust.
Doing so can cause malfunction.
Do not use excessive force to lift the side frame, which can
pull the gas spring out of the leg.
Doing so can cause malfunction or damage the instrument.
Do not apply a high tensile load on the gas spring.
Doing so can cause malfunction or damage the instrument.
10
I
RD500 (Frame Parts only)
A
Leg Base Unit (Bass side) ....................................... 1
B
Leg Base Unit (Treble side) ..................................... 1
C
Stay ......................................................................... 1
D
Rack pipe ................................................................ 1
E
Multi-Frame Clamp (RDC-10) ................................. 4
YX500FT (Xylophone set)
F
Xylophone Main Unit .............................................. 1
G
Resonators (Natural tone side) ............................... 1
H
Resonators (Accidental tone side) .......................... 1
I
Knob Head Bolt/Spring Washer/Washer .......... 4 set
F
A
B
C
D
G
H
E
Con rmation of Packing Contents
Before assembling the frame, please take a look at the parts list and make sure that all of the required parts
are accounted for.
* If any parts are missing, please contact the dealer where the frame was purchased.
11
2,3
Wingnut
A
(
B
)
Center rail
C
Diagonal stay support
1
Fully insert the end of stay
C
with its notch facing up into the joint on
leg base
A
, then rmly tighten the wing bolt.
* Pay attention to the stay’s orientation when attaching. Parts are marked with
letters to assist with assembly. (Refer to the diagram below.)
2
Remove the wing nut, washers, and spring washers on the center rail
of the bass side leg base
A
, slide the C-shaped end of the diagonal
stay support
C
onto the bolt on the center rail then tighten the wing
nut rmly with washer and spring washer.
3
Use the same procedure to connect the clamp and diagonal stay
support on stay
C
to the center rail on the treble side leg base
B
.
4
Loosen the clamp screws on both ends of the rack pipe
D
and fasten
the clamps onto the poles on the upper leg section.
The rack pipe can be attached so its clamp side is either on the
audience side or the player’s side of the pole. Decide how much space
you need between the rack pipe and tone bars and attach the rack
pipe accordingly.
* Please make sure that the YAMAHA logo is not placed upside-down.
5
Firmly tighten all bolts.
Assembly of the Multi-Frame is complete.
When disassembling the multi-percussion rack, follow the
assembly steps in reverse order.
4
Tighten
Pole
D
Rack pipe
A
(
B
Rack frame
D
Rack pipe
1,3
C
Stay
Notch
Wing bolt
A
(
B
)
Leg base
1
4
6
6
2
4
A
Leg base
B
Leg base
D
Rack pipe
3
C
Stay
3
Spring washer
Washer
Tighten
Match “Y”
Match “Z”
Assembly
First, assemble the Multi-Frame (RD500) then attach the xylophone set (YX500FT) onto the frame.
For safety reasons, make sure that assembly of the Multi-Frame and attaching of the instrument is
carried out with two or more persons, and that you assemble the product in an area with adequate
space.
D
Rack pipe
Rack frame
Center rail
12
6
7
B
Rack
frame
F
Xylophone Main Unit
8,9
Diagram A
(Above 23°C: Shallow notch)
Diagram B
(Below 23°C: Deep notch)
Bass side
Treble side
Resonators
(Natural tone side)
Resonator rest
2
1
Resonators
(Accidental tone side)
Sideboard
B
Rack frame
Marker
Mounting frame
L bracket
Notch
Resonator rest
Sideboard
Next, attach the instrument to the rack.
* Do not let the resonators hit against the legs or other part of the frame during their installation.
Washer
I
Spring washer
Knob head
bolt
6
Align the bolt holes on the underside of the sideboard with the holes
on the L-shaped bracket attached to the rack frame and set the in-
strument
F
onto the rack.
Use the white marker* on the sideboard (on its outer side) as
an aid when aligning. The marker should be centered on the L-
shaped bracket for proper alignment.
* The YX335 does not have a white marker.
7
Use the supplied bolts, washers, and spring washers
I
attached
to the instrument to attach the instrument from the underside of the
rack (4 locations).
8
First pass the resonators through the instruments from underneath
the rail and then mount the treble end into the resonator rest.
9
Next, mount the bass side. Pass the end of the resonators through
the space in the center of the resonator rest as shown in the dia-
gram, and fi t it into the notch in the resonator rest.
When room temperature is 73.4°F (23°C) and above,
set the
resonators into the shallow notches of the resonator rest (Diagram A).
When room temperature is 73.4°F (23°C) and below,
set the
resonators into the deeper notches of the resonator rest (Diagram B).
10
Use the same procedure to install the other set of resonators.
After assembly is complete, rmly tighten all bolts.
To disassemble, follow the assembly steps in
reverse order.
13
Adjusting the Height of the Playing Surface
Never loosen the slide guide fixing bolts when the
xylophone is not mounted on the rack or when the
legs (
A
and
B
) are not attached to the rack.
When adjusting the height of the playing surface,
make sure that adjustment is carried out by at least
two people. If a single person must unavoidably
carry out adjustment, do not move the guides any
more than 2 slide guide memory positions at a time.
1. While supporting both bass and treble sides of the frame with your
hands, loosen the slide guide xing bolts.
2. Gas springs in the rack slide guides will cause the instrument to rise
automatically. After adjusting the instrument to the required height,
tighten the xing bolts rmly. Use the guides on the slide guides to ad-
just the playing surface so it is parallel to the oor.
Speci cations
Scale Range
YX500FT
* Speci cations subject to change without notice.
YX500FT
Range: F45 – C88 (3-1/2 octave)
Standard Pitch: 442Hz
Bars: Acoustalon (FRP), Brown Urethane Finish
Bar sizes: 38.1 mm (1-1/2") wide
23 mm (7/8") thick
Resonators: Steel Pipe, Light Gold Acrylic Coating
Frame: Beech, Black Enamel Matte Finish
Dimensions (W x D x H):
137.5 x 75 x 31 cm (54-3/8" x 29-1/2" x 12-3/16")
Weight: 27 kg (59 lbs 8 oz)
RD500
Height Adjustment:
Gas spring type
85 – 100 cm (33-7/16" x 39-3/8")
(With the YX500FT attached:
Measured from the accidental tone bars)
83 – 98 cm (32-11/16" x 38-9/16")
Caster Diameter: 150 mm (5-7/8")
Dimensions (W x D): 164 x 107 cm (64-9/16" x 42-1/8")
(Full depth including casters)
Weight: 33 kg (72 lbs 12 oz)
Removing the Gas Springs
Never remove the gas springs except when discarding.
1. Loosen all four slide guide xing bolts when the instrument is mounted on the rack, raise the rack frame all of the way
up, then tighten the four slide guide xing bolts. (Refer to the diagram shown above for part names.)
2. Remove the instrument from the rack and disassemble the rack so that the leg sections are removed from the frame.
(Reverse the order of the instructions in the assembly section on pages 11-12.)
3. Loosen the two slide guide xing bolts and slide the slide guide sections out of the leg column.
4. Loosen the gas spring attached to the bottom of the slide guide and remove.
* The two parts are threaded and screw together.
Slide guide
xig bolt
Rack frame
Slide guide
Leg column
Joint (w/bolt)
Gas spring
WV49220 1007 R0 Printed in Japan
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Yamaha RD-500 Návod k obsluze

Typ
Návod k obsluze
Tato příručka je také vhodná pro